GKM-11 220VAC MonoPhase Overvoltage & Undervoltage Protection Relay

★★★★★ 4.8 133 reviews

US$20.17
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by www.lusorealestategroup.com
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$20.17
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Aug 24
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by www.lusorealestategroup.com
Free 30-day returns Details

Product details

Management number 247507648 Release Date 2026/08/16 List Price US$20.17 Model Number 247507648
Category

Phase Monitoring RelaysGeneralVoltage control relays are designed to protect devices with sensitive operating voltage values from failures that may be caused by mains voltage.Usage and Working PrincipleMake the connections of the device in accordance with connection scheme. Set the required settings of the device according to the operating voltage values of te load. When the device is energized, if the voltage values are normal according to the set values, the relay gets activated and the relay LED() is turned on. When the voltage values go out of the set values, the related fault LED is on, it waits until the delay time (DT), after the time has elapsed, the relay gets de-activated and the relay LED goes out. When the voltages to their normal values, the device waits until the reset time (RT), after the time has elapsed the relay gets activated and the relay LED is turned on.Disable to ProtectionThe High Voltage Protection function is deactivated when the HV control knob is set to Off. The Low Voltage Protection function is deactivated when the LV control knob is set to Off. The Off stage is limited to 140V. If the voltage falls below 140V while in this stage, the relay is deactivated and the LV Led is flashes.Relay Activated/De-activated StatusRelay is Activated: 2 (COM) and 3 (NC) short circuit, 1 (NC) and 2 (COM open circuit.Relay is De-activated: 2 (COM) and 1 (NC) short circuit, 3 (NC) and 2 (COM) open circuit.Required Settings and Error NotificationsHV Control Knob: High Voltage Set Value, when the voltage rises above this value, HV LED is on.LV Control Knob: Low Voltage Set Value, when the voltage drops below this value, LV LED is on.OT Control Knob: Delay Time, is the time to wait before entering the ailure.RT Control Knob: Reset Time, is the time to wait for the relay to pull when the voltages to norma.Protection FunctionsHigh Voltage Protection - To enter the error state: If the voltage, goes above the high voltage set value, the HV LED is on, the device waits until the set delay time (DT), after the time has elapsed the relay gets de-activated and the relay LED is off.High Voltage Protection - Exiting the error state: When voltage, lower than 5 volts of the set high voltage set value, the device waits for the reset timé (RT). After the time passes, the HV LED is off the relay gets activated and the relay LED is on.Low Voltage Protection - To enter the error state: If the voltage, goes below the low voltage set value, the LV LED is on, the device waits until the set delay time (DT), after the time has elapsed the relay gets de-activated and the relay LED is off.Low Voltage Protection - Exiting the error state: When voltage is higher than 5 volts of the set high voltage set value, the device waits for the reset time (RT). After the time passes, the LV LED is off the relay gets activated and the relay LED is on.MaintenanceSwitch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemicalmight damage the device. Make sure device works after cleaningWarningsPlease use the device according to the manual.Don't use the device in wet.Include a switch and circuit breaker in the assembly.Put the switch and circuit breaker nearby the device, operator can easily.Mark the switch and circuit breaker as releasing connection for device.SpecificationsOperating Voltage(Un)....: 220V ACOperating Frequency.......: 50/60 Hz.<;6VAOperating Temperature..: -20°C.....+55°CHigh Voltage Set(U>)...........: 230V - 300V+OFF<;)............: 150V - 210V+OFFDelay Time.......................: 0,5sec - 20sec.Relay Time.......................: 0,5sec - 20sec.Display.....................: 3x LEDsConnection Type.....: Terminal connectionContact.................:5A/250V AC (Resistive Load)Cable Diameter.................: 2,5mm²Weight................................: Max. 100gr.Mounting...........................: Vertical assembled in the panel or assembled on the din rail<;2000meterDimensionsConnection diagram

  • Phase Monitoring Relays
  • GKM-11 220VAC MonoPhase Overvoltage & Undervoltage Protection Relay
ASIN B0HDBDFNNM
Model TGVNUFDEK
Brand Name TGVNUFDEK
Part Number TGVNUFDEK
Manufacturer TGVNUFDEK

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.8 out of 5
★★★★★
133 ratings | 55 reviews
How item rating is calculated
View all reviews
5 stars
87% (116)
4 stars
2% (3)
3 stars
1% (1)
2 stars
0% (0)
1 star
10% (13)
Sort by

There are currently no written reviews for this product.